Booster Pump Head Calculation Xls (FREE)
Please note that this is a simplified example and actual calculations may require more complex formulas and considerations.
The friction head loss is calculated using the Darcy-Weisbach equation: booster pump head calculation xls
Hf = 0.02 * (1000/0.1) * (1.5^2/2*9.81) = 2.29 m Hs = 20 - 10 = 10 m Hm = 10% of H = 0.1 * (2.29 + 10) = 1.23 m H = 2.29 + 10 + 1.23 = 13.52 m Please note that this is a simplified example
The static head is the difference in elevation between the suction and discharge points: booster pump head calculation xls